adi-insite-ca
ADI US App
ADI Global Distribution
ADI a Resideo company
menu

Control Panel Modules

Filter Results

Showing  1 - 28 of 110
content loaded
Secutron MMX-BB-4002R Back Box for 1 or 2 MRI-4000-M Series Modules, Red
Sign In for Dealer Pricing
image of 5t-pcs100
Sign In for Dealer Pricing
image of 5t-mri4070
Sign In for Dealer Pricing
image of 5t-mri4041;image of 5t-mri4041
Sign In for Dealer Pricing
image of 5t-mri4040m
Sign In for Dealer Pricing
image of 5t-mri4042
Sign In for Dealer Pricing
image of 5t-mri4040
Sign In for Dealer Pricing
SAE FE-A1349 LHD Monitor Module Interface
Sign In for Dealer Pricing
Honeywell CH19000301 Interface Module Accessory, RS-485
Sign In for Dealer Pricing
image of 5t-alc480
Sign In for Dealer Pricing
image of 5t-mgd32
Sign In for Dealer Pricing
image of 5t-mri4070m;image of 5t-mri4070m
Sign In for Dealer Pricing
SigCom 693-0457 DVS-Remote Mic Interface Board
Sign In for Dealer Pricing
image of ds-ds7457if
Sign In for Dealer Pricing
Federal Signal K859901990A Supervisory Diode Module
Sign In for Dealer Pricing
image of 5t-mr2300a
Sign In for Dealer Pricing
Sale
image of fl-mmf301a
MMF-301AFL-MMF301A

Key Features

  • Built-in type identification automatically identifies this device as a monitor module to the panel
  • Powered directly by two-wire SLC loop. No additional power required
  • High noise (EMF/RFI) i mmunity
  • Supervises IDC wiring and connection of external power source
  • SEMS screws with clamping plates for ease of wiring
  • Direct-dial entry entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems
  • LED flashes during normal operation
Sign In for Dealer Pricing
Sign In for Dealer Pricing
fire-lite cmf-300 addressable control module;fire-lite cmf-300a intelligent addressable control module
CMF-300AFL-CMF300A

Key Features

  • Built-in type identification automatically identifies these devices to the control panel.
  • Internal circuitry powered directly by two-wire SLC loop. The CMF-300(A) module requires power (for horns, strobes, etc.).
  • Integral LED"blinks" green each time a communication is received from the control panel and turns on steady redWhen activated.
  • High noise immunity (EMF/RFI).
  • The CMF-300(A) may be used to switch 24-volt NAC power.
  • Wide viewing angle of LED.
  • SEMS screws with clamping plates for wiring ease.
  • Direct-dial entry of address: 01- 159 for MS-9600 series panels, 01 - 99 on MS-9200UDLS and MS-9050UD.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-aim4a
AIM-4AFL-AIM4A

Key Features

  • Mounting 4” X 4” X 2.8” Standard box
  • Weight 5 oz.
  • Indoor Operating Temperature 32°F to 120°F (0°C to 49°C)
  • Operating Voltage Range 15-30VDC
  • Standby Current 0.0A
  • Alarm Current AIM-1A - 10mA Average / AIM-4A - 0.0A
  • Output Circuit Rating 150mA Max. at 24VDC 3.75W Max 25/70 VAC
  • Inrush Current AIM-1A - 75mA Max. at 24 VDC / AIM-4A - 0.0A
  • Terminals 12-18 AWG
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    fire-lite mmf-300-10a ten-input monitor module
    MMF-300-10AFL-MMF30010A

    Key Features

    • Ten addressable Class B or five addressable Class A initiating device circuits
    • Rotary address switches
    • Mounting hardware included
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    fire-lite mdf-300a addressable control module
    MDF-300AFL-MDF300A

    Key Features

    • Built-in identification automatically recognizes this device as a monitor module
    • SEMS screws with clAing plates for & easierWiring
    • LED that flashes green during normal states, and turns a solid red during an alarm
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    fire-lite mmf-302-6a six zone interface module
    MMF-302-6AFL-MMF3026A

    Key Features

    • Transmits the status of a zone of two-wire detectors to the fire alarm control panel.
    • Six addressable Class B or three addressable Class A initiating device circuits.
    • Status conditions are reported as normal, open, or alarm.
    • Supervises the zone of detectors and the connection of the external power supply.
    • Removable plug-in terminal blocks.
    • Status indicators for each point.
    • Unused addresses may be disabled.
    • Rotary address switches.
    • Class A or Class B operation
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    fire-lite i300(a) fault isolator module
    I300AFL-I300A

    Key Features

    • Directly powered by SLC loop without the need for external power
    • LED that blinks to indicate normal conditions and turns solidWhen short circuit conditions are detected
    • High noise i mmunity
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Sale
    image of fl-mmf300a;image of fl-mmf300a
    MMF-300AFL-MMF300A

    Key Features

    • Built-in type identification automatically identifies this device as a monitor module to the control panel
    • Powered directly by two-wire SLC loop. No additional power required
    • High noise (EMF/RFI) i mmunity
    • SEMS screws with clamping plates for ease of wiring
    • Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems
    • LED flashes during normal operation and latches on steady to indicate alarm
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    fire-lite 2-wire detector monitor module
    MMF-302AFL-MMF302A

    Key Features

    • MMF-300(A) is a standard-sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices.
    • MMF-301(A) is a miniature monitor module a mere 1.3" (3.302cm) used to supervise a Style B (Class B) circuit of dry-contact input devices.
    • MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit.
    • MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses.
    • Built-in type identification automatically identifies these devices as a monitor module to the control panel.
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Secutron MMX-BB-4002R Back Box for 1 or 2 MRI-4000-M Series Modules, Red
    MMX-BB-4002R5T-MMXBB400

    Key Features

  • Provides easy access to 2 modules while keeping them protected
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-pcs100
    PCS-1005T-PCS100

    Key Features

  • Compatible with 3G4010 and 3G4010CF models
  • Universal wireless alarm communicator support
  • Efficient power supply interface board
  • Ensures reliable power connectivity
  • Ideal for security system installations
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4070
    MRI-40705T-MRI4070

    Key Features

  • The MRI-4046 Supervised Output Module is designed to be used with compatible fire alarm control units
  • Any combination of MRI-4000 series devices up to 240 can be connected on a single SLC
  • Mounts in a standard 4” square or double gang electrical back box
  • Indicating LED provides module status
  • Self Restoring feature – Module automatically restores the entire circuit to normal condition when the short circuit is removed
  • Short Circuit isolation, allowing the remaining devices to continue operating
  • Easily identify a faulty SLC section
  • No jumpers or special hardware setting for specific applications
  • Self-restoring feature
  • No device address required
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4041;image of 5t-mri4041
    MRI-40415T-MRI4041

    Key Features

  • Any combination of MRI-4000 series devices up to 240 can be connected on a single SLC
  • Fits in a single gang junction box
  • Indicating LED provides module status
  • Fast, reliable contact monitoring
  • Will automatically set inputs to single Class A or dual Class B according to the configuration sent by the fire alarm panel
  • No EOL resistor required when input is in Class A operation
  • Monitors two (2) independent circuits in Class B using one (1) module address
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4040m
    MRI-4040-M5T-MRI4040M

    Key Features

  • Supports either 6 class A or 12 class B inputs
  • No EOL resistor required when input is in Class A operation
  • Monitor 12 independent input circuits with only one address when configured as class B
  • Fast, reliable contact monitoring
  • Affordable and space efficient
  • Mounting clip for DIN rail and plug-In terminal blocks for fast and easy installation
  • Each input has LED indicators to signal Alarm (RED) or Trouble (YELLOW)
  • Additional LEDs to show SLC communication status and if a short circuit has occurred
  • Compatible with MR-400, MR-401 and MMX-4000 Fire alarm control panels
  • Up to 2 modules can be mounted on UL/ULC listed backbox enclosure, MMX-BB-4002R
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4042
    MRI-40425T-MRI4042

    Key Features

  • The MRI-4042 Conventional Zone Module is designed to be used with compatible fire alarm control units
  • Any combination of MRI-4000 series devices up to 240 can be connected on a single SLC
  • Mounts in a standard 4” square or double gang electrical back box
  • Indicating LED provides module status
  • Compatible with conventional two wire or 4-20mA devices
  • Temperature range 32ºF to 120ºF (0ºC to 49ºC)
  • Each MRI-4042 module monitors the current used by the devices and reports alarms and troubles accordingly
  • Compatible with a large array of 2 wire devices
  • When configured for conventional devices, the module will automatically handle Class A or Class B lines
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4040
    MRI-40405T-MRI4040

    Key Features

  • Any combination of MRI-4000 series devices up to 240 can be connected on a single SLC
  • Mounts in a standard 4” square or double gang electrical back box
  • Indicating LED provides module status
  • Fast, reliable contact monitoring
  • Will automatically set inputs to single Class A or dual Class B according to the configuration sent by the fire alarm panel
  • No EOL resistor required when input is in Class A operation
  • Monitors two (2) independent circuits in Class B using one (1) module address
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    SAE FE-A1349 LHD Monitor Module Interface
    FE-A1349O6-FEA1349
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Honeywell CH19000301 Interface Module Accessory, RS-485
    CH19000301HCH19000301
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-alc480
    ALC-4805T-ALC480

    Key Features

  • 480 Point Dual Loop Adder
  • MR-401 System Component
  • Provides two addressable (SLC) loops
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mgd32
    MGD-325T-MGD32

    Key Features

  • Common control inputs for system management
  • Includes System Reset and Signal Silence
  • Supports Auxiliary Disconnect and Fire Drill
  • Lamp Test and Acknowledge functions
  • Enhances operational efficiency
  • Compact and user-friendly design
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mri4070m;image of 5t-mri4070m
    MRI-4070-M5T-MRI4070M

    Key Features

  • Provides 8 isolator sections which are electrically isolated from each other
  • Allows the SLC loop to continue operating when a short circuit occur on one section of the loop
  • Each isolation section has an LED indicator to signal normal condition (blinks) or short circuit condition (solid), allowing easy identification of a faulty SLC section
  • Self-restoring capability on each section once a short circuit is removed
  • Affordable and space efficient
  • Mounting clip for DIN rail and plug-In terminal blocks for fast and easy installation
  • Any unused section can be left unconnected without affecting other sections
  • Compatible with MR-400, MR-401 and MMX-4000 Fire alarm control panels
  • Up to 2 modules can be mounted on UL/ULC listed backbox enclosure, MMX-BB-4002R
  • Up to 6 modules can be mounted on UL/UL listed backbox enclosure, MMX-BB-4006R
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    SigCom 693-0457 DVS-Remote Mic Interface Board
    693-0457AN-6930457
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Honeywell 49840600 Special Video XO USB IFace IO MIO+EIO
    49840600H49840600
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of ds-ds7457if
    DS7457IFDS-DS7457IF

    Key Features

    • Address settings through DIP switches
    • Compact enough to fit within most back boxes and enclosures
    • Power-limited and supervised input zones
    Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of le-anu48
    ANU-48LE-ANU48

    Key Features

  • Includes input for eight software programmable switches, maintained on momentary contact
  • Provides output for up to 48 remote LEDs or driver circuits
  • Installed up to 3,000'(914.4 m) from the control panel, and up to 15 additional annunciators can be connected
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Federal Signal K859901990A Supervisory Diode Module
    K859901990AQF-CPSUPERDI

    Key Features

  • All Call Point models feature a GRP enclosure that is UV stable, anti-static, flameproof, and resistant to heat, impact, and corrosion. The GRP enclosure makes Federal Signal’s Call Points extremely durable to withstand pressure, damage, and environmental elements, making it an ideal solution for all industrial, hazardous, and Fire applications.
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of pl-scm4
    SCM-4PL-SCM4

    Key Features

  • One Class B (Style B) contact monitoring input
  • Powered directly from 2 wire SLC Loop
  • SLC Class A (Style 6,7) and Class B (Style4)
  • Mounts on a standard 4" or double gang box
  • Wiring terminals accept 22 to 14 AWG
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    image of 5t-mr2300a
    MR-2300-A5T-MR2300A

    Key Features

  • Two MR-2300-A modules are required to convert all twelve initiating circuits on an MR-2312 series panel
  • Sign In for Dealer Pricing
    Sign In for Dealer Pricing
    Showing 1 - 28 of 110